KITCHEN PACKAGES Bundle & save more•HUGE BLACK FRIDAY SALE Save Up to 50%•GUARANTEED BEST PRICING No one beats us•KITCHEN PACKAGES Bundle & save more•HUGE BLACK FRIDAY SALE Save Up to 50%•GUARANTEED BEST PRICING No one beats us•KITCHEN PACKAGES Bundle & save more•HUGE BLACK FRIDAY SALE Save Up to 50%•GUARANTEED BEST PRICING No one beats us•KITCHEN PACKAGES Bundle & save more•HUGE BLACK FRIDAY SALE Save Up to 50%•GUARANTEED BEST PRICING No one beats us•

PTAC Units: Sizes, Heat Pump vs Electric Heat and Sleeves

PTAC units heat and cool one room through a 42-inch wall sleeve. Learn BTU sizing, heat pump vs electric heat, 230 vs 265 volt power and sleeve basics.

By Shop Appliances Team· 5 min read
White Friedrich PTAC unit installed under a window in a hotel room beside a desk and chair

A PTAC, short for packaged terminal air conditioner, is the through-the-wall unit you see under the window in many hotel rooms, apartments, senior living rooms and offices. One self-contained box cools the room and also heats it, either with a heat pump or with electric heat strips. The unit slides into a metal wall sleeve with an outdoor grille, so it can be swapped later without opening the wall.

This guide compares six PTAC units from Friedrich, GE Zoneline and Hotpoint using the details on each product page. Browse all PTAC units and wall sleeves, or see our Friedrich air conditioner guide for the brand's window and wall units.

The short version
  • PTACs in this guide list 7,100 to 15,100 BTU of cooling.
  • Heat pump models heat efficiently in mild weather; electric heat models use heat strips.
  • Units run on 230 volts or 265 volts, so match the unit to the building's power.
  • Every model here is about 42 inches wide and 16 inches tall to fit a standard PTAC sleeve.
  • Plug type and amperage vary, so check the outlet before you order.

Our top picks at a glance

Compare them side by side

265-Volt Electric Heat Pick: Friedrich PDE09R3SGR3 ZoneAire Premier PTAC with Electric Heat, 265 Volts

1265-Volt Electric Heat Pick
Friedrich PDE09R3SGR3 42 inch ZoneAire Premier PTAC with 10000 BTU Cooling Capacity, 3.5k Watts Electric Heat and 265 Volts in White
$1,169$1,379Save $210
See today's price

The PDE09R3SGR3 is a Friedrich ZoneAire Premier PTAC for 265-volt buildings. It lists 10,000 BTU of cooling, 12,000 BTU of electric heat (3.5 kW), a 7-20P plug and Quietmaster technology with heavy insulation and vibration dampening. The LED display can show the set point or the room temperature.

Why we like it
  • 10,000 BTU cooling
  • Quietmaster technology
  • LED display
Keep in mind
  • Needs 265-volt power
Best for: Hotels and apartments wired for 265 volts

265-Volt Heat Pump Pick: Friedrich PDH07R3SGR3 ZoneAire Premier PTAC with Heat Pump, 265 Volts

2265-Volt Heat Pump Pick
Friedrich PDH07R3SGR3 42 inch ZoneAire Premier PTAC with 7300 BTU Cooling Capacity, 6000 BTU Heat Pump and 265 Volts in White
$1,289$1,519Save $230
See today's price

The PDH07R3SGR3 is a heat pump version of the ZoneAire Premier for 265 volts. It lists 7,300 BTU of cooling and 6,000 BTU of heat pump heating, a 7-20P plug and the same Quietmaster sound reduction design.

Why we like it
  • Heat pump heating
  • 7,300 BTU cooling
  • Quietmaster technology
Keep in mind
  • Needs 265-volt power
Best for: Small rooms in mild climates

12,000 BTU Electric Pick: Friedrich PDE12R3SGR3 ZoneAire Premier PTAC with Electric Heat, 265 Volts

312,000 BTU Electric Pick
Friedrich PDE12R3SGR3 42 inch ZoneAire Premier PTAC with 12300 BTU Cooling Capacity, 3.5k Watts Electric Heat and 265 Volts in White
$1,179$1,389Save $210
See today's price

The PDE12R3SGR3 is the larger electric heat ZoneAire Premier for 265 volts. It lists 12,300 BTU of cooling and 12,000 BTU of heat from 3.5 kW electric heat, with a 7-20P plug and an easy-to-read LED display.

Why we like it
  • 12,300 BTU cooling
  • 3.5 kW electric heat
  • LED display
Keep in mind
  • Needs 265-volt power
Best for: Larger guest rooms and studios

Zoneline Heat Pump Pick: GE AZHS15DCXXA Zoneline Heat Pump PTAC, 208/230 Volts

4Zoneline Heat Pump Pick
GE AZHS15DCXXA PTAC Zoneline Heat Pump Packaged Terminal Air Conditioner with 15000 BTU, Corrosion Protection, 208/230V
$1,310
See today's price

The AZHS15DCXXA is a GE Zoneline heat pump unit with 15,100 BTU of cooling and 13,500 BTU of heating on 208/230 volts. It lists electronic touch controls with an LED display, a corrosion protection package, R454B refrigerant and design and assembly in America.

Why we like it
  • 15,100 BTU cooling
  • Corrosion protection
  • Designed and assembled in America
Keep in mind
  • Needs a 230-volt circuit
Best for: Large rooms and coastal buildings

Hotpoint Electric Heat Pick: Hotpoint AHES09D3XXA PTAC with 3.5 kW Electric Heat

5Hotpoint Electric Heat Pick
Hotpoint AHES09D3XXA 42 inch PTAC with 9400 BTU Cooling Capacity, 3.5 kW Electric Heat, 2 Fan Speeds and Auto Dimming Display in White
$763
See today's price

The AHES09D3XXA is a Hotpoint PTAC with 9,400 BTU of cooling and 3.5 kW electric heat on 230 volts. It lists 2 fan speeds, 4 temperature-limiting options, an auto dimming display, automatic emergency heat, freeze and overheat protection and auto power recovery.

Why we like it
  • 9,400 BTU cooling
  • Auto dimming display
  • Temperature limiting
Keep in mind
  • Electric heat uses more power than a heat pump
Best for: Rental units and guest rooms

Hotpoint Heat Pump Pick: Hotpoint AHHS12D3XXA PTAC with Heat Pump

6Hotpoint Heat Pump Pick
Hotpoint AHHS12D3XXA PTAC with 12400 BTU Cooling Capacity, 11000 BTU Heat Pump and 230/280 Volts, 20 Amps in White
$845
See today's price

The AHHS12D3XXA is a Hotpoint heat pump PTAC with 12,400 BTU of cooling and 11,000 BTU of heat pump heating. It lists R32 refrigerant, electric heat backup, 2 fan speeds, an auto dimming display and self-diagnostics.

Why we like it
  • Heat pump with electric backup
  • 12,400 BTU cooling
  • Self-diagnostics
Keep in mind
  • Needs a 230-volt circuit
Best for: Year-round use in apartments

PTAC Units Compared

Friedrich PDE09R3SGR3 42 inch ZoneAire Premier PTAC with 10000 BTU Cooling Capacity, 3.5k Watts Electric Heat and 265 Volts in White
Friedrich 9k Electric
Friedrich PDH07R3SGR3 42 inch ZoneAire Premier PTAC with 7300 BTU Cooling Capacity, 6000 BTU Heat Pump and 265 Volts in White
Friedrich 7k Heat Pump
Friedrich PDE12R3SGR3 42 inch ZoneAire Premier PTAC with 12300 BTU Cooling Capacity, 3.5k Watts Electric Heat and 265 Volts in White
Friedrich 12k Electric
GE AZHS15DCXXA PTAC Zoneline Heat Pump Packaged Terminal Air Conditioner with 15000 BTU, Corrosion Protection, 208/230V
GE Zoneline 15k
Hotpoint AHES09D3XXA 42 inch PTAC with 9400 BTU Cooling Capacity, 3.5 kW Electric Heat, 2 Fan Speeds and Auto Dimming Display in White
Hotpoint 9k Electric
Hotpoint AHHS12D3XXA PTAC with 12400 BTU Cooling Capacity, 11000 BTU Heat Pump and 230/280 Volts, 20 Amps in White
Hotpoint 12k Heat Pump
ModelPDE09R3SGR3PDH07R3SGR3PDE12R3SGR3AZHS15DCXXAAHES09D3XXAAHHS12D3XXA
Price$1,169$1,289$1,179$1,310$763$845
Heat typeElectric heatHeat pumpElectric heatHeat pumpElectric heatHeat pump
Cooling10,000 BTU7,300 BTU12,300 BTU15,100 BTU9,400 BTU12,400 BTU
Heating12,000 BTU6,000 BTU12,000 BTU13,500 BTU12,000 BTU11,000 BTU
Voltage265 volts265 volts265 volts230 volts230 volts230 volts
Width42"42"42"42"42 2/5"42 2/5"
Depth21 1/2"21"21 1/2"20 13/16"20 9/10"20 9/10"
ViewViewViewViewViewView

How to Size a PTAC

PTACs are sized by cooling BTU. Smaller rooms such as a single hotel room or bedroom often use about 7,000 to 9,000 BTU, while larger rooms, studios and rooms with lots of sun or glass move up to 12,000 to 15,000 BTU. If you are replacing an older unit, the old nameplate is a good starting point, but changes like new windows or insulation can change what you need.

  • About 7,000 to 9,000 BTU for smaller rooms
  • About 12,000 to 15,000 BTU for larger or sunny rooms
  • Check the heating BTU too, not just cooling
  • Ask an HVAC pro for a load calculation on unusual rooms

Heat Pump or Electric Heat?

A heat pump PTAC moves heat from outdoors into the room, so it uses less power to heat in mild weather. Most heat pump units switch to electric backup heat when it gets very cold. An electric heat PTAC warms the room with heat strips, which is simple and works in any weather but uses more power. In colder climates or where heat runs for months, a heat pump often makes sense; for rooms that need only occasional heat, electric heat is fine.

Voltage, Plugs and Wall Sleeves

PTACs come in 230/208-volt and 265-volt versions, and the two are not interchangeable. Many hotels and commercial buildings use 265 volts, while most apartments use 230/208 volts. Each unit also has a specific plug and amperage, such as the 7-20P plug on the Friedrich 265-volt models. The chassis slides into a 42-inch wall sleeve with an exterior grille. When you replace a unit, you can often keep the existing sleeve if it is in good shape. For through-the-wall units that are not PTACs, see our Frigidaire through-the-wall AC guide.

How to Choose a PTAC Unit

  1. 01

    Check the power230/208 volts or 265 volts, plus plug and amps.

  2. 02

    Pick the heat typeHeat pump or electric heat.

  3. 03

    Size the coolingMatch BTU to the room size and sun.

  4. 04

    Confirm the sleeve42-inch sleeve and exterior grille in good shape.

Our picks by budget

Related guides

See every PTAC unit by BTU, heat type and voltage.

Shop PTAC units

Frequently Asked Questions

What is a PTAC unit?

A PTAC, or packaged terminal air conditioner, is a self-contained through-the-wall unit that cools and heats one room. It slides into a wall sleeve with an outdoor grille.

What is the difference between a heat pump and electric heat PTAC?

A heat pump PTAC moves heat from outside and uses less power in mild weather. An electric heat PTAC uses heat strips, which work in any weather but use more power.

What size PTAC do I need?

Smaller rooms often use about 7,000 to 9,000 BTU, and larger or sunny rooms about 12,000 to 15,000 BTU. The units in this guide list 7,300 to 15,100 BTU of cooling.

Can I put a 230-volt PTAC in a 265-volt building?

No. PTACs are built for either 230/208 volts or 265 volts, so match the unit to the building's power supply and outlet.

What size wall sleeve does a PTAC use?

The units in this guide are about 42 inches wide and 16 inches tall, the standard PTAC size, and fit a 42-inch wall sleeve.

FriedrichGEptac unitthrough-the-wallheat pumpelectric heatwall sleeveZoneline